3 Recommended Fixes For Onan Generator Fault Code 13

onan generator fault code 13
onan generator fault code 13

Camping enthusiasts enjoy going out on long trips under harsh weather climates. They explore new areas and are mostly away from their homes. However, the main problem that they will is the lack of power.

Even if you have a motorhome with you, the batteries in these vehicles are not powerful enough to last several weeks. This is especially the case when you have to use electrical appliances like cameras throughout your trip.

Considering this, the best solution for these people is to install a generator in their vehicle. Onan is one of the best companies when it comes to these products. Talking about this, one important feature that you will use is the fault code system.

This notifies you about a problem helping you pin down its causes. This way you can get rid of the issue as soon as possible. We will be using this article to provide you with some troubleshooting steps that can be used on Onan Generator Fault Code 13.

Dealing with Onan Generator Fault Code 13 Through The Best Solutions

1. Switch Off Your Breakers

Running into a problem on your generator while you are on a trip can be quite annoying. This is because there is no way to visit a workshop and this is one of the most important devices that you might want to use. Although, the fault code makes it extremely easy for people to pin down the reason for their issue.

Fault code 13 refers to your generator being unable to produce enough voltage. The first thing that you should do in this case is switching off the breakers on your generator, vehicle as well as main power outlets. If the generator is still showing the same error code then you will have to move on to the next steps.

2. Governor Rod Might Be Loose

Sometimes when the issue on your generator is related to its voltage, there is a high chance that your governor rod might be loose. These are springs that have to be tightly connected to work properly.

You can find them on the teethed bar on your generator however, this might vary depending on your model. This is why it is better that you try checking the manual for some help. This should contain information about where the governor rod springs exactly are. You can then try tightening them to fix your problem.

3. Breaker Might Be Faulty

In some cases, the breakers on your generator can die out which will also cause problems like these. Considering this, you should start by switching on the breaker installed on your generator and see if the device works fine. If it gives you the error code again then this might be faulty.

Replacing it should fix your problem, however, if it does not. Then your only option will be to contact the support team for Onan. The team is quite helpful and should help in finding what is causing the problem. Just make sure that you follow their instructions carefully to fix your issue.